The circuit board incorporates a fuse (100mA, 125V) for electronic equipment. If devices other than the
original AC adapter are used or a large electrical current is applied, the fuse will be blown for safety
purposes. If the fuse is blown, the unit must be inspected and repaired. As the fuse forms a fixed part of
the unit and cannot be easily disassembled by the customer, please consult your nearest Tanita sales office
or agent when the fuse needs to be replaced.
[Maintenance]
This is a precision manufactured and accurately calibrated product. Please observe the following instructions.
Never disassemble or adjust the equipment, as this may cause malfunctions. The equipment should only
be inspected in accordance with the regulations in each country.
When not in use for a long time, unplug the AC Adapter from the wall socket.
When not in use for a long time, remove the batteries before storing the equipment.
Do not wipe the equipment with corrosive chemicals (benzine, cleaner, etc.). Please use a neutral
detergent to clean the equipment.
Avoid subjecting the equipment to excessive shocks or vibrations.
When disposing of this unit, please do so in accordance with the prevailing regulations in each country.
If an unauthorised person attempts to disassemble or repair any of the part, the warranty will become
invalid. When the unit malfunctions, please consult your nearest Tanita sales office or agent.
[Instructions for Measurement]
Please observe the following instructions for accurate measurement.
Measurement may not be possible on a surface that is strongly vibrating. In such cases transfer the
equipment to a stable surface with little or no vibration.
When the equipment has been transferred to another location with a temperature difference of more than
20˚C, leave at least two hours before using.
While taking measurements, please keep any persons using transmitters, such as a mobile phone, away
from the unit to avoid causing margin errors.
<Usage Conditions>
<Storage Conditions>
<Power Source>
Applications
This equipment has been calibrated as a precision weighing instrument and can be used to certify weights and/or
business transactions.
It can be used to obtain reference data during medical examinations, such as periodic checkups, and can help the
prevention of obesity.
54
Warning
To prevent electric shocks,
Do not insert or remove the power plug with wet hands.
To prevent fire hazards,
Always use a correctly wired 230V AC not multiple extension cords.
Caution
To prevent the spread of infections,
Always clean the Weighing platform after use. Sterilize the platform with an appropriate alcohol-based
cleaning fluid before each use.
Installation of the Weighing Platform
Ensure the weighing platform is placed on a level and stable surface. If the equipment is used when the
Platform is unstable, for example because not all the feet are on a level surface, there is a risk that it will
topple over and it will be impossible to obtain an accurate measurement.
To avoid the risk of injury and damage to the equipment, never jump on the platform.
How to handle the equipment when moving it
Since the Platform is heavy, please lift it by holding the Platform firmly with both hands so that you do
not drop it.
AC Adapter
Ensure that the adapter supplied (model A30930G) is always used with this equipment. Other adapters
may cause malfunctions.
Battery
When changing batteries, ensure that the new batteries are inserted with the correct polarity / . If the
polarity is incorrect, then the batteries may leak and damage the equipment.
Warning
This symbol indicates the risk of death or serious injury if the safety
instructions are ignored and the equipment is misused.
Caution
This symbol indicates the risk of physical injury and/or damage to the
equipment if the safety instructions are ignored and the equipment is
misused.
This symbol indicates general precautions that should be taken when using
this equipment.
Safety Notes
Caution Symbols
In this Instruction Manual and the descriptions on the equipment, there are various caution symbols that will enable
you to use this equipment safely and correctly so that harm to you and other people and loss of your property will
be prevented.
The symbols and their meanings are as follows. Please understand them well before proceeding with the Instruction
Manual.
Temperature Range for Use : 0°C / 35°C
Relative Humidity : 30% / 80% (without condensation)
Temperature Range of Environment : -10°C / 50°C
Range of Relative Humidity : 10% / 90% (without condensation)
To avoid malfunctions, do not store the equipment in direct sunlight, significant temperature changes, the risk of
dampness, a large amount of dust, in the vicinity of fires or where there is a risk of receiving vibrations or shocks.
Value Range
230VAC
50Hz
65mA
Voltage Range
Frequency Range
Electric Current Range
Descargue el manual en Español (PDF, 1.1 MB)
(Piense en el medioambiente y solo imprima este manual si es de verdad necesario)

Loading…

Puntuación

Dé su opinión de la Tanita BWB-800MA Báscula calificando el producto. ¿Quiere compartir su experiencia con este producto o hacer una pregunta? Deje un comentario en la parte inferior de la página.
¿Estás satisfecho con elTanita BWB-800MA Báscula?
No
Sea el primero en calificar este producto
0 votos

Únase a la conversación sobre este producto

Aquí puedes compartir lo que piensas sobre Tanita BWB-800MA Báscula. Si tiene alguna pregunta, primero lea atentamente el manual. Puede solicitar un manual utilizando nuestro formulario de contacto.

Más sobre este manual

Entendemos que es bueno tener un manual en papel para tus Tanita BWB-800MA Báscula. Siempre puedes descargar el manual desde nuestro sitio web e imprimirlo tú mismo. Si deseas tener un manual original te recomendamos contactar con Tanita. Es posible que puedan proporcionar un manual original. ¿Estás buscando el manual de tu Tanita BWB-800MA Báscula en otro idioma? Elija su idioma preferido en nuestra página de inicio y busque el número de modelo para ver si lo tenemos disponible.

Especificaciones

Marca Tanita
Modelo BWB-800MA
Categoría Básculas
Tipo de archivo PDF
Tamaño del archivo 1.1 MB

Todos los manuales para Tanita Básculas
Más manuales de Básculas

Preguntas frecuentes sobre Tanita BWB-800MA Báscula

Nuestro equipo de atención al cliente busca información útil sobre los productos y responde a las preguntas frecuentes. Si encuentra inexactitudes en las preguntas frecuentes, indíquenoslo usando nuestro formulario de contacto.

Mi báscula muestra un peso demasiado bajo cuando me pongo en ella. ¿Por qué? Verificado

Para obtener el mejor resultado, la báscula debe estar en una superficie dura y nivelada. Cuando la báscula se coloca sobre una alfombra, por ejemplo, esto puede influir en la medición.

Ha sido de gran ayuda (2520) Leer más

¿Qué es el IMC? Verificado

IMC significa Índice de Masa Corporal y se puede calcular dividiendo su peso en kilogramos por su estatura en metros al cuadrado. Por ejemplo, alguien con un peso de 70 kilos y una estatura de 1,75 metros tiene un IMC de 22,86. Un IMC entre 18,5 y 25 se considera saludable.

Ha sido de gran ayuda (1790) Leer más

La pila de mi dispositivo está oxidada. ¿Puedo seguir usándolo con seguridad? Verificado

Sí, todavía puede usar el dispositivo con seguridad. En primer lugar, retire la pila oxidada. Nunca la toque con sus manos desnudas al hacerlo. A continuación, limpie el compartimento de la pila con un bastoncillo de algodón mojado en vinagre o zumo de limón. Déjelo secar e inserte nuevas pilas.

Ha sido de gran ayuda (765) Leer más

¿Puedo usar una báscula con los pies mojados? Verificado

Depende de la escala. Al utilizar una balanza de diagnóstico es necesario que sus pies estén secos para poder realizar correctamente las mediciones.