WPE DIESEL GENERATORS
FEATURES
3
EN
FEATURES
WPE Diesel generator possesses the following features:
This series diesel generator adopts super-light type, air
cooled, 4-stoke direct injection diesel engine and has two
starting options:
1. Remote Start (6500SVWRC & 6500SV3WRC)
2. Electric start.
They are equipped with large capacity fuel tank, circuit
protector, A.C and sometimes D.C voltage outputs, low oil
pressure alarm and automatic stopping device.
The diesel generator serves as an UPS stand-by power
supply in many different applications including open
working site, construction and field army. Emergency
power of poultry farm, fishery, forestry, garden, hotel,
shop, and office.
This operation manual tells you how to operate and
service your new diesel generator. Please read it before
using the diesel generator to ensure proper handing
and operation. Following these instructions carefully will
keep your diesel generator in the best working condition,
allowing to prolong the life of your diesel generator.
If you have any questions concerning your new product
or any of the information given in this manual, please
contact service@bpeholdings.co.uk.
PARAMETERS
The generators can generate specified power when used
in the following conditions:
Altitude: < 1000m
Ambient Temperature: 5 to 40°C
Relative humidity: <90%
WARNING
Exhaust/mufflers and gases are very hot to
touch. DO NOT add or install any exhaust/muffler
extensions, by doing so you will void any warranty
offered.
Preventing burns
NEVER touch or handle exhaust/muffler, engine when
generator is running or hot, always leave approx 30
minutes for the exhaust/muffler & engine to cool before
handling.
IMPORTANT
Please read and understand this operation manual to
insure safe operation, and pay high attention to the
following main points of operation otherwise it may
cause personal injury and damage to equipment.
Preventing fires
The fuel of this diesel engine is light diesel fuel , so petrol,
kerosene or bio-diesel etc must NEVER be used. Diesel
with dyes is not recommended and if used monthly
maintenance is strongly recommended otherwise it will
result in degraded engine performance and(or) damage
to engine.
Wipe away all fuel spills with a clean cloth. Keep
petrol, kerosene, matches and other explosives and
inflammable substance away from the generator,
because the temperature around the exhaust muffler is
very high during operation. To prevent fire hazards and
to provide adequate ventilation, keep the generator at
least 1.5 meter away from buildings, structures and other
equipment during operation.
Operate the generator on a flat level surface, there may
be fuel spillage or poor operation if the generator is tilted.
WARNING
NEVER run the generator on MAX watts for longer
than ten (10) minutes, by doing so you will cause the
engine to overheat and then stall; risking fire. If in
event this happens immediately stop the generator
and allow to cool for minimum 30 mins.
Preventing exhaust gas inhalation
Exhaust gas contains poisonous carbon monoxide.
Always use the generator in outdoor locations minimum
1.5m anyway from window, doors or opening.
Generators MUST never be used indoors, in garages,
cabins, out building, sheds or any confined spaces
including vehicles and vehicle compartments.
Electric shocks, short circuits
In order to avoid electric shocks or short circuit, do not
touch the generator, when either it or your hands are wet.
This generator is not waterproof , so it should NEVER be
used in a place exposed to rain, snow or water sprays.
The generator should be ground to prevent electric
shocks. Please connect a length of heavy wire between
the generators ground terminal and an external ground
device, ground rod or stake - minimum 200mm deep.
Do not connect any equipment to the generator before
you start it.
WARNING
Most appliance motors require more than their rated
wattage for start up. Do not exceeded the current
limit specified for any one socket. NEVER overload
or run generator for long periods of time on Max
watts. If generator shows signs of overheating STOP
immediately and allow to cool for minimum 30mins.
Descargue el manual en Español (PDF, 2.33 MB)
(Piense en el medioambiente y solo imprima este manual si es de verdad necesario)

Loading…

Puntuación

Dé su opinión de la Warrior 6500SVWRC-(EU) Generador calificando el producto. ¿Quiere compartir su experiencia con este producto o hacer una pregunta? Deje un comentario en la parte inferior de la página.
¿Estás satisfecho con elWarrior 6500SVWRC-(EU) Generador?
No
Sea el primero en calificar este producto
0 votos

Únase a la conversación sobre este producto

Aquí puedes compartir lo que piensas sobre Warrior 6500SVWRC-(EU) Generador. Si tiene alguna pregunta, primero lea atentamente el manual. Puede solicitar un manual utilizando nuestro formulario de contacto.

Más sobre este manual

Entendemos que es bueno tener un manual en papel para tus Warrior 6500SVWRC-(EU) Generador. Siempre puedes descargar el manual desde nuestro sitio web e imprimirlo tú mismo. Si deseas tener un manual original te recomendamos contactar con Warrior. Es posible que puedan proporcionar un manual original. ¿Estás buscando el manual de tu Warrior 6500SVWRC-(EU) Generador en otro idioma? Elija su idioma preferido en nuestra página de inicio y busque el número de modelo para ver si lo tenemos disponible.

Especificaciones

Marca Warrior
Modelo 6500SVWRC-(EU)
Categoría Generadores
Tipo de archivo PDF
Tamaño del archivo 2.33 MB

Todos los manuales para Warrior Generadores
Más manuales de Generadores

Manual de uso Warrior 6500SVWRC-(EU) Generador

Productos relacionados

Categorias relacionadas