Manual de uso Tetra Whisper 10-30i Filtro de acuario

¿Necesita un manual para su Tetra Whisper 10-30i Filtro de acuario? A continuación puedes ver y descargar el manual en PDF gratis en español. Este producto actualmente tiene 3 preguntas frecuentes, 2 comentarios y tiene 0 votos. Si este no es el manual que desea, , contáctenos.

¿Su producto tiene algún defecto y el manual no ofrece ninguna solución? Vaya a Repair Café para solicitar un servicio de reparación gratuito.

Manual de uso

Loading…

Whisper
®
Internal
Power Filter
1. Replace Tetra
®
Whisper
®
Bio-Bag
®
Cartridge Monthly.
2.
Never: Clean or replace Bio-Foam
®
unless
damaged. Discoloration is normal and
desirable. If excessive buildup occurs,
rinse gently with room temperature
dechlorinated water.
3.
Clean impeller yearly.
5-10i
10-30i
20-40i
Troubleshooting Guidelines
Setup
IMPORTANT:
Always unplug the Internal Filter before
inspecting or disassembling
for any reason.
18-12599
1. Attach the filter hanger to the track on the back of the filter
by aligning the water drops as shown (Fig. 1).
2.
Clip the filter to the back wall of your aquarium frame (Fig. 2). If the hanger
doesn't fit, you may need to order separate suction cups (see spare parts list
on back panel to order).
3. Insert the Filter Cartridge and Bio-Foam
®
as shown (Fig. 3). (Note: the front of
the Bio-Foam
®
is marked “front” and should face the front of the Internal Filter.)
4. See diagram for positioning and max and min water levels. To adjust the
height of your filter, simply slide the filter up or down along the hanger track.
If you can't position the filter to your desired water level, you may need
to order suction cups (see spare parts list to order). For low water level
terrariums, you may set the filter on a ledge or aquarium bottom (Fig. 5).
5. Once the filter and water level is within the recommended parameters,
plug in the filter. Avoid using sand in the aquarium as this clogs the filter.
• Avoid placing sand in the aquarium when using this filter.
• Unplug the unit to clean the filter with a clean wet cloth. If needed,
add white distilled vinegar to the cloth, and rinse thoroughly.
• If the Bio-Foam
®
pad is clogged, gently wash with room temperature water
treated with AquaSafe
®
water conditioner to protect beneficial bacteria.
• When medicating fish, remove the carbon from the Bio-Bag
®
, as
carbon absorbs most medications.
• To service the impeller yearly, or if the motor is noisy, unplug the filter and remove it from the aquarium.
Remove the motor (see illustration A), open its cover, and flush debris with clean water. Soak the impeller in
distilled white vinegar using a cotton swab to wipe debris, and rinse. Replace the motor into the filter and install
it in the aquarium using the instructions in this manual.
• It takes a few weeks for new aquarium water to cycle. “Cycling” a fish tank means growing healthy bacteria
on a new filtration system so it filters out dangerous toxins. Tetra
®
SafeStart
®
aquarium bacteria cycles your
aquarium immediately, so you can add fish right away.
Fig. 1
Fig. 2 Fig. 3 Fig. 4 Fig. 5
UNITED PET GROUP, A DIVISION OF SPECTRUM BRANDS, INC.
UNITED PET GROUP, UNA DIVISIÓN DE SPECTRUM BRANDS, INC.
UNITED PET GROUP, UNE FILIALE DE SPECTRUM BRANDS, INC.
3001 COMMERCE ST., BLACKSBURG, VA 24060
1-800-526-0650 • www.tetra-fish.com
® REGISTERED TRADEMARK AND TM TRADEMARK OF SPECTRUM BRANDS, INC.
MARCA COMERCIAL REGISTRADA ® Y MARCA COMERCIAL TM DE SPECTRUM BRANDS, INC.
® MARQUE DÉPOSÉE ET TM MARQUE DE COMMERCE DE SPECTRUM BRANDS, INC.
© 2017 SPECTRUM BRANDS, INC. • MADE IN CHINA • HECHO EN CHINA • FABRIQUÉ EN CHINE
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
This document contains proprietary and confidenal informaon and is the property of United Pet Group Inc. UPG is part of Pet, Home & Garden, a division of Spectrum Brands, Inc, .
The document is loaned on the condion that neither it nor the informaon contained therein shall be disclosed to others without the express consent of UPG. The document shall be returned to UPG upon its request.
1
XX-XXXX
PRELIMINARY
JLS
XXXXXX
CAT_26038-600
1
X
1
1:1
FINISH
MATERIAL
CAT_26038-600
DRWN
CHKD
APPV
DES
DATE
REVISION
ECN
LTR
DO NOT SCALE DRAWING
FINISH
MATERIAL
REV.
OF
1
SHEET
C
DWG. NO.
CAD FILE:
SIZE
SCALE
CAD GENERATED DRAWING,
DO NOT MANUALLY UPDATE
3001 Commerce St., Blacksburg, Virginia 24060 USA (540)951-5400 FAX: (540)951-5415
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DECIMALS ANGLES
2 PLC DEC
0.02
1/2
3 PLC DEC
0.005
FRACTIONAL
1/16
Model 5-10i Models 10-30i, 20-40i
Click Fit
OR
Illus. A
Water Level
Niveau d’eau
Minimum Water Level
Niveau d’eau minimum
Intake Area
Zone d’aspiration
IMPORTANT SAFETY INSTRUCTIONS
WARNING – To guard against injury, basic safety precautions should be observed, including the following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
DANGER – TO AVOID POSSIBLE ELECTRIC SHOCK, special care should be taken since water
is employed in the use of aquarium equipment. For each of the following situations, do not attempt repairs by yourself; return the
appliance to an authorized service facility for service or discard the appliance:
1. Unplug the appliance before installing, repositioning, cleaning, or
removing the appliance.
2. If the appliance shows any sign of abnormal water leakage, immediately
unplug it from the power source.
3. Carefully examine the appliance after installation. It should not be plugged in.
4. Do not operate any appliance if it has a damaged cord or plug, or if it is
malfunctioning or has been dropped or damaged in any manner.
5. To avoid the possibility of the appliance plug or receptacle getting wet, position
aquarium stand and tank to one side of a wall-mounted receptacle to prevent
water from dripping onto the receptacle or plug. A “drip loop,” shown in the
figure below, should be arranged by the user for each cord connecting an
aquarium appliance to a receptacle. The “drip loop” is the part of the cord below
the level of the receptacle, or the connector if an extension cord is used, to prevent
water traveling along the cord and coming in contact with the receptacle.
If the plug or receptacle does get wet, DON’T unplug the cord. Disconnect the
fuse or circuit breaker that supplies power to the appliance. Then,
unplug and examine for presence of water in the receptacle.
6. Close supervision is necessary when any appliance is used by or near children.
7. To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, and the like.
8. Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before cleaning.
Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.
9. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the appliance
manufacturer may cause an unsafe condition.
10. Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.
11. Make sure an appliance mounted on a tank is securely installed before operating it.
12. Read and observe all the important notices on the appliance.
13. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than
the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.
14. This appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in a polarized
outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified
electrician. Never use with an extension cord unless plug can be fully inserted. Do not attempt to defeat this safety feature.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING – To guard against injury, basic safety precautions should be observed, including the following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
DANGER – TO AVOID POSSIBLE ELECTRIC SHOCK, special care should be taken since water
is employed in the use of aquarium equipment. For each of the following situations, do not attempt repairs by yourself; return the
appliance to an authorized service facility for service or discard the appliance:
1. Unplug the appliance before installing, repositioning, cleaning, or
removing the appliance.
2. If the appliance shows any sign of abnormal water leakage, immediately
unplug it from the power source.
3. Carefully examine the appliance after installation. It should not be plugged in.
4. Do not operate any appliance if it has a damaged cord or plug, or if it is
malfunctioning or has been dropped or damaged in any manner.
5. To avoid the possibility of the appliance plug or receptacle getting wet, position
aquarium stand and tank to one side of a wall-mounted receptacle to prevent
water from dripping onto the receptacle or plug. A “drip loop,” shown in the
figure below, should be arranged by the user for each cord connecting an
aquarium appliance to a receptacle. The “drip loop” is the part of the cord below
the level of the receptacle, or the connector if an extension cord is used, to prevent
water traveling along the cord and coming in contact with the receptacle.
If the plug or receptacle does get wet, DON’T unplug the cord. Disconnect the
fuse or circuit breaker that supplies power to the appliance. Then,
unplug and examine for presence of water in the receptacle.
6. Close supervision is necessary when any appliance is used by or near children.
7. To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, and the like.
8. Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before cleaning.
Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.
9. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the appliance
manufacturer may cause an unsafe condition.
10. Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.
11. Make sure an appliance mounted on a tank is securely installed before operating it.
12. Read and observe all the important notices on the appliance.
13. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than
the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.
14. This appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in a polarized
outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified
electrician. Never use with an extension cord unless plug can be fully inserted. Do not attempt to defeat this safety feature.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING – To guard against injury, basic safety precautions should be observed, including the following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
DANGER – TO AVOID POSSIBLE ELECTRIC SHOCK, special care should be taken since water
is employed in the use of aquarium equipment. For each of the following situations, do not attempt repairs by yourself; return the
appliance to an authorized service facility for service or discard the appliance:
1. Unplug the appliance before installing, repositioning, cleaning, or
removing the appliance.
2. If the appliance shows any sign of abnormal water leakage, immediately
unplug it from the power source.
3. Carefully examine the appliance after installation. It should not be plugged in.
4. Do not operate any appliance if it has a damaged cord or plug, or if it is
malfunctioning or has been dropped or damaged in any manner.
5. To avoid the possibility of the appliance plug or receptacle getting wet, position
aquarium stand and tank to one side of a wall-mounted receptacle to prevent
water from dripping onto the receptacle or plug. A “drip loop,” shown in the
figure below, should be arranged by the user for each cord connecting an
aquarium appliance to a receptacle. The “drip loop” is the part of the cord below
the level of the receptacle, or the connector if an extension cord is used, to prevent
water traveling along the cord and coming in contact with the receptacle.
If the plug or receptacle does get wet, DON’T unplug the cord. Disconnect the
fuse or circuit breaker that supplies power to the appliance. Then,
unplug and examine for presence of water in the receptacle.
6. Close supervision is necessary when any appliance is used by or near children.
7. To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, and the like.
8. Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before cleaning.
Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.
9. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the appliance
manufacturer may cause an unsafe condition.
10. Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.
11. Make sure an appliance mounted on a tank is securely installed before operating it.
12. Read and observe all the important notices on the appliance.
13. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than
the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.
14. This appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in a polarized
outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified
electrician. Never use with an extension cord unless plug can be fully inserted. Do not attempt to defeat this safety feature.
SAVE THESE INSTRUCTIONS
TWO YEAR LIMITED WARRANTY:
United Pet Group, a division of Spectrum Brands, Inc. (UPG), warrants this
Internal Filter against defects in material or workmanship for two years from the date of original purchase, subject to the
conditions and exceptions stated below. Your sales receipt is your Proof-of-Date-of-Purchase. If the Internal Filter exhibits
such a defect, UPG will repair or replace it, our option, without cost for parts or labor. The Internal filter must be shipped
postage paid to UPG. Proof-of-Date-of-Purchase is required. You are responsible for proper shipping. Call customer
service at 1-800-526-0650 for return authorization and shipping address. This warranty does not cover damage caused
by accident, misuse, abuse, or failure to follow the instructions accompanying this Internal Filter. All implied warranties,
including any implied warranty of merchantability or fitness for any purpose are limited to two year. Fish and plant loss,
personal injury, property loss or damage (direct, incidental or consequential) resulting from the use of the Internal Filter
are not covered by this warranty. Because some states/provinces do not allow the exclusion or limitation of incidental or
consequential damages, or allow limitations on how long an implied warranty lasts, the above limitations or exclusion
may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from
state/province to state/province.
APPLIANCE
AQUARIUM
POWER
CORD
DRIP
LOOP
Questions or Missing Parts?
Call Customer Service at
1-800-526-0650
Monday through Friday
8:00 AM to 5:30 PM ET
1 1 1
2 2 2
3 3 3
4 4 4
5-10i 10-30i 20-40i
Replacement Parts List
KEY
1
2
3
4
ITEM DESCRIPTION
Bio-Foam
®
Suction Cups
Impeller
Hanger Assembly
10-30i
25997
19613
19610
19632
5-10i
25996
19613
19609
19631
20-40i
25997
19613
19611
19632
MODEL NUMBER
Parts Diagram & Identification
Descargue el manual en Español (PDF, 5.54 MB)
(Piense en el medioambiente y solo imprima este manual si es de verdad necesario)

Loading…

Puntuación

Dé su opinión de la Tetra Whisper 10-30i Filtro de acuario calificando el producto. ¿Quiere compartir su experiencia con este producto o hacer una pregunta? Deje un comentario en la parte inferior de la página.
¿Estás satisfecho con elTetra Whisper 10-30i Filtro de acuario?
No
Sea el primero en calificar este producto
0 votos

Únase a la conversación sobre este producto

Aquí puedes compartir lo que piensas sobre Tetra Whisper 10-30i Filtro de acuario. Si tiene alguna pregunta, primero lea atentamente el manual. Puede solicitar un manual utilizando nuestro formulario de contacto.

Lusa walker 13-06-2023
Necesito el colgador de filtro para el 10-30i...cuanto??

responder | Ha sido de gran ayuda (0) (Traducido por Google)
Lusa walker 13-06-2023
Necesito el colgador de filtro para el 10-30i...cuanto?? 19632

responder | Ha sido de gran ayuda (0) (Traducido por Google)

Más sobre este manual

Entendemos que es bueno tener un manual en papel para tus Tetra Whisper 10-30i Filtro de acuario. Siempre puedes descargar el manual desde nuestro sitio web e imprimirlo tú mismo. Si deseas tener un manual original te recomendamos contactar con Tetra. Es posible que puedan proporcionar un manual original. ¿Estás buscando el manual de tu Tetra Whisper 10-30i Filtro de acuario en otro idioma? Elija su idioma preferido en nuestra página de inicio y busque el número de modelo para ver si lo tenemos disponible.

Especificaciones

Marca Tetra
Modelo Whisper 10-30i
Categoría Filtros de acuarios
Tipo de archivo PDF
Tamaño del archivo 5.54 MB

Todos los manuales para Tetra Filtros de acuarios
Más manuales de Filtros de acuarios

Preguntas frecuentes sobre Tetra Whisper 10-30i Filtro de acuario

Nuestro equipo de atención al cliente busca información útil sobre los productos y responde a las preguntas frecuentes. Si encuentra inexactitudes en las preguntas frecuentes, indíquenoslo usando nuestro formulario de contacto.

Tengo un filtro de acuario con esponjas. ¿Con qué frecuencia debo reemplazarlas? Verificado

Las esponjas deben ser reemplazadas varias veces al año. Después de un tiempo las esponjas se desgastarán y no filtrarán el agua de manera óptima.

Ha sido de gran ayuda (87) Leer más

Tengo un filtro de acuario con carbón activo. ¿Con qué frecuencia debo reemplazarlo? Verificado

El carbón activo pierde su función al cabo de unas dos semanas y debe ser reemplazado para seguir filtrando el agua adecuadamente.

Ha sido de gran ayuda (39) Leer más

¿Cuál es la diferencia entre un filtro interno y externo? Verificado

Los filtros internos se colocan en el interior del acuario y se utilizan generalmente para acuarios más pequeños. Los filtros externos se colocan fuera del acuario y se utilizan para acuarios más grandes. Los filtros externos suelen tener una gran capacidad y pueden estar sin mantenimiento durante mucho tiempo.

Ha sido de gran ayuda (37) Leer más
Manual de uso Tetra Whisper 10-30i Filtro de acuario

Productos relacionados

Categorias relacionadas